Products
Amorphous alloy dry type transformer is made of amorphous alloy with the structure of three-phase five-column, the core is clamped with sheet or molding frame. HV winding is adapted with the segmented hierarchical structure, meanwhile, LV winding is adapted with foil structure. Amorphous alloy dry-type transformers have many advantages as excellent energy-saving, low loss, powerful anti-short circuit capability, low partial-discharge, and low noise.
1.Phase: phases
2.Rated power: 100kVA
3.Primary voltage: 33kV
4.Secondary voltage: 0.4kV
5.Frequency: 50Hz/60Hz
6.Vector group: Dyn11
7.Insulation class: H/F Class
1.Low loss, especially no-load loss, 70% lower than the value of GB standard, economy, and energy saving.
2.Low noise, low partial discharge, high reliability, outstanding anti-short-circuit capability, high anti-lighting impulse capacity.
3.HV winding is cast with epoxy resin at a vacuum state with pressure.
4.Simulating analysis is used in the core model to avoid the resonance and lower the noise. Simulation calculation and analysis of lighting impulse wave is also used in the HV winding model to improve anti- lightning impulse capability.
Technical characteristics for 100kVA 33kV amorphous alloy dry type transformer
Transformer type | Cast resin dry type transformer |
Transformer Model | 100kVA 33/0.4kV |
Short circuit impedance | 6% |
Noise Level | 50dB |
Cooling mode | AN/AF |
Winding material | Copper/Aluminum |
Core material | Amorphous alloy |
Degree of protection | IP00-IP55 |
HV tapping | +/-2*2.5% |
Insulation material | Cast resin (HV) Pre-impregnated (LV) |
Insulation level | Primary: 70kV AC Secondary: 3kV AC |
BIL | 170kV for primary circuit |
Type of installation | Indoor |
Maximum attitude | <1000m |
Standards | IEC60076-11 |
Application: urban power grids, high-rise buildings, business centers, theaters, hospitals, hotels, tunnels, subways, underground power plants, laboratories, stations, docks, airports, combined substations, and other important places.
After-sales Service: We have a professional aftersales engineer team, each aftersales engineer has more than 3 years of experience. And we also have localized technical backup to offer timely support in Malaysia, South Africa, Egypt, Dubai, UAE, Brazil.
IP protective enclosure:
The standard transformers produced by our company are without the case and their protection level is IP20. We can also provide IP30 or IP40 if you require. The case can be made by common steel plates, stainless steel plants, or aluminum alloy and can be acid-washed,parkerised, and powder-painted.
Temperature controller:
The temperature controller displays are installed on the low voltage side of the case, which is reliable and convenient for users to check.
1.Pearl Electric covers a factory area of 100,000 square meters, with more than 70,000 square meters of up-to-date workshop building.
2.The workshops are equipped with more than 600 units of modern manufacturing equipment, advanced in China and abroad, such as the fully automatic vacuum resin-casting equipment imported from Germany HÜBERS company, the automatic slitting lines for silicon steel sheet manufacturing, 600mm automatic transverse shear line for transformer core manufacturing.
3.The complete set of transformer testing equipment is equipped in the test center, including the shielded measurement room for local partial discharge and noise tests. Pearl Electric has the capability to carry out all the type tests and routine tests (except the short-circuit test) within the test center, thus greatly satisfying various test requirements for transformer product research, design, and manufacturing.
We focus highly on the development of design and research in accordance to the demand of market.
Design team:
1.Pearl Electric has more than 500 employees, among which more than 39% have a college education background .
2.4 doctoral-degree engineers, 16 senior engineers, 34 intermediate engineers, 39 junior engineers.
3.A half of the engineers have more than 5-year experience in the electrical industry.
Training:
1.Offer timely training for products and knowledge of new techniques.
2.Encourage engineers and workers to study for new qualifications included high-level education and skill qualification.
New product:
Water-cooled phase-shifting transformer for main pump frequency converter.
1.Class 1E transformer for the nuclear island of nuclear power plant.
2.Pumped storage super large capacity converter dry-type transformer.
1.Do a lot of research about transformer design included temperature field calculation, lightning impulse analysis, transformer noise & vibration analysis, 3D simulation design, etc.
2.Being the major drafter of 8 items national standards, 14items national standards amendment, 8 items industry standards, and 19 items industry standards amendment.
3.Obtained 11 invention patents, 27 utility model patents, 7 software copyright approval and registration, 47 technical papers published in national magazines or journals, and has the independent intellectual property rights of the core technology of the products.
Copyright © Pearl Electric Co., Ltd.